top of page

APPLICATION · BUILDING MATERIALS R&D

Heat Flux Sensors for Advanced Building Materials, Roofing & Insulation Testing

New materials work by changing how heat is absorbed, stored, reflected or released. Temperature alone cannot show that. A heat flux sensor measures the heat actually moving through the material, in real time.

FluxTeq PHFS-09e large-area heat flux sensor for building materials testing

6 studies

summarized below, from adaptive roof tiles to mass timber and asphalt

3.1×

lower cooling energy reported for an adaptive roof tile tested with a PHFS-09e (Device, 2024)

Ultra-09

our most sensitive plate, for insulation and low heat flux

From $420

PHFS-09e large-area sensor

RESEARCH SUMMARIZED BELOW WAS PUBLISHED IN

Device (Cell Press)  ·  Frontiers in Built Environment  ·  Materials and Structures  ·  Journal of Physics: Conference Series

Why Heat Flux Sensors for Advanced Building Materials?

A material may stay cool because it reflects sunlight, stores heat, exchanges heat with ventilation air, emits infrared radiation, or simply resists conduction. FluxTeq sensors are used to measure heat transfer through experimental roofs, insulation panels, adaptive surfaces, mass timber systems, thermal mass assemblies, asphalt concrete and bio-based materials.

Thermal conductivity and R-value

 

Steady-state heat flux and temperature difference across a sample of known thickness.

Adaptive and radiative surfaces

 

Heat gained or rejected by switchable, reflective and emissive roof materials.

Roof and green roof heat transfer

 

Heat flow through roof assemblies under real sun, rain and seasonal conditions.

Thermal mass and heat storage

 

How much heat a wood, concrete or phase-change element absorbs and releases, and when.

Dynamic insulation

 

Heat exchange in breathing walls and ventilated panels.

Model validation

 

Measured surface heat flux to check heat-transfer models of new materials.

Recommended products

large area PHFS-09e heat flux sensor

PHFS-09e

 

Large-area heat flux sensor for material, roof and panel testing.

 

$420    View sensor →

FluxTeq Ultra-09 ultra-sensitive heat flux plate

Ultra-09

 

Ultra-sensitive plate for insulation, thermal mass and very low heat flux.

 

$675    View sensor →

FluxTeq FluxDAQ+ heat flux and thermocouple data logger

FluxDAQ+

 

Multi-channel heat flux and temperature logging for research setups.

 

$670    View logger →

Published Papers

In published research

The studies below were conducted by independent researchers. FluxTeq did not design, perform or validate the experiments. They are shown as examples of how FluxTeq sensors and DAQ systems have been used in building materials research.

DEVICE (CELL PRESS) · 2024

PEER-REVIEWED JOURNAL

 

Passively Adaptive Radiative Switch for Thermoregulation in Buildings

 

MEASURED WITH

PHFS-09e

 

Read the full paper →

The study. Developed a tile-like passive radiative switch that moves between heating and cooling states with no electrical power. Wax-motor actuators open and close louvers, switching the surface between a black, solar-absorbing state and a white, infrared-emitting state. The authors present it as a roofing-tile concept for cutting both heating and cooling energy.

 

How heat flux was measured. A FluxTeq PHFS-09e sensor measured heat flux in rooftop tests at the University of California, Santa Barbara, logged every 0.5 seconds.

 

Reported result. The adaptive tile lowered cooling energy by 3.1× and heating energy by 2.6×.

adaptive roof passive thermaoregulation radiative heating cooling heat flux sensor phfs-09e

FRONTIERS IN BUILT ENVIRONMENT · 2021

PEER-REVIEWED JOURNAL

 

The Design of Mass Timber Panels as Heat-Exchangers (Dynamic Insulation)

 

MEASURED WITH

Ultra-09

 

Read the article →

The study. Investigated how mass timber panels can work as heat exchangers, or “breathing walls,” by adding optimized air channels through the material. The aim is one low-carbon element that combines structure, ventilation and thermal functions, reducing the need for added insulation, cladding and HVAC components.

 

How heat flux was measured. FluxTeq Ultra-09 sensors were mounted on both surfaces of the test panels to measure heat flux through the timber.

MATERIALS AND STRUCTURES · 2026

PEER-REVIEWED JOURNAL

 

A Comparative Analysis of the Thermal Conductivity Measurement of Asphalt Concrete Under Steady-State and Transient Heat Transfer Conditions

 

MEASURED WITH

Ultra-09

 

Read the full paper →

The study. Compared steady-state and transient methods for measuring the thermal conductivity of asphalt concrete. Twelve mixtures were prepared with different aggregate sources, air-void levels and maximum aggregate sizes. The work bears on pavement durability, urban heat island mitigation and asphalt solar collectors.

 

How heat flux was measured. The custom steady-state setup used a FluxTeq Ultra-09 heat flux sensor (9.2 × 8.7 cm), and its results were compared with a Hot Disk TPS transient method.

JOURNAL OF PHYSICS: CONFERENCE SERIES · 2021

PEER-REVIEWED PROCEEDINGS

 

Synchronized Coupling of Thermal Mass and Buoyancy Ventilation: Wood Versus Concrete

 

RELEVANT SENSOR

Ultra-09

 

Read the full paper →

The study. Tested scaling rules for coupling internal thermal mass with buoyancy ventilation, comparing wood and concrete thermal masses in small test chambers in Alabama and Montreal. The question: can properly sized wood thermal mass perform like concrete when thickness and surface area are optimized?

 

The role of heat flux. Front and back surface temperatures and surface heat flux of the thermal mass were measured to track when heat was absorbed and released.

EXPRES · 2022

CONFERENCE PAPER

 

Green Roof Temperature Distribution Monitoring System

 

SPECIFIED SENSOR

PHFS-09e

 

The study. Describes a green roof monitoring project at the University of Pécs in Hungary: an extensive green roof of about 45 m² and two control roof sections of similar size, one with added XPS insulation.

 

The role of heat flux. The monitoring system was designed to record roof temperatures, solar radiation, water balance and heat transfer through the roof over time, with PHFS-09e sensors specified for the heat flux measurement.

IAPRI MEMBER CONFERENCE · 2023

CONFERENCE PAPER

 

Biochar Composites for Sustainable Thermal Packaging Applications

 

RELEVANT SENSOR

PHFS-09e

 

The study. Studied biochar composites with a bio-based binder as insulation for temperature-controlled packaging, as alternatives to expanded polystyrene (EPS) for vaccine, food and pharmaceutical transport.

 

Reported result. Several biochar-binder combinations achieved thermal performance comparable to EPS in R-value and thermal conductivity testing.

Common questions

 

How do I measure the thermal conductivity of a new material?

Place a heat flux sensor against a sample of known thickness between a warm and a cool surface. At steady state, thermal conductivity is the heat flux times the thickness, divided by the temperature difference across the sample.

 

Which sensor for insulation or other low heat flux?

The Ultra-09. It is the most sensitive FluxTeq sensor. The PHFS-09e suits roofs, panels and most material tests.

 

Can the sensors be used on a roof outdoors?

Yes. The Device (2024) study above ran a PHFS-09e in rooftop tests. Tell us the exposure and duration and we will advise on mounting and protection.

 

Can I get custom sizes or volume pricing?

Yes. FluxTeq makes custom sensor sizes and supplies sensors in volume. The PHFS-OEM is $70 per sensor with a minimum order of four.

 

Testing a new building material? Tell us the application, temperature range and quantity.

bottom of page